Zinc: The Goldilocks metal for bioabsorbable stents?

Apr. 30, 2013 ? In 2012, more than 3 million people had stents inserted in their coronary arteries. These tiny mesh tubes prop open blood vessels healing from procedures like a balloon angioplasty, which widens arteries blocked by clots or plaque deposits. After about six months, most damaged arteries are healed and stay open on their own. The stent, however, is there for a lifetime.

Most of the time, that's not a problem, says Patrick Bowen, a doctoral student studying materials science and engineering at Michigan Technological University. The arterial wall heals in around the old stent with no ill effect. But the longer a stent is in the body, the greater the risk of late-stage side effects. For example, a permanent stent can cause intermittent inflammation and clotting at the implant site. In a small percentage of cases, the tiny metal segments that make up the stent can break and end up poking the arterial wall.

"When the stent stays in place 15, 20 or 25 years, you can see these side effects," says Bowen. "It's not uncommon to have a stent put in at age 60, and if you live to be 80, that's a long time for something to remain inert in your body."

That's why researchers are trying to develop a bioabsorbable stent, one that would gradually -- and harmlessly -- dissolve after the blood vessel is healed.

Many studies have investigated iron- and magnesium-based stents. However, iron is not promising: it rusts in the artery. Magnesium, on the other hand, dissolves too quickly. "We wondered, 'Isn't there something else?'" Bowen said. "And we thought, 'Why not zinc?'"

So they placed tiny zinc wires in the arteries of rats. The results were amazing. "The corrosion rate was exactly where it needed to be," Bowen said. The wires degraded at a rate just below 0.2 millimeters per year -- the "magic" value for bioabsorbable stents -- for the first three months. After that, the corrosion accelerated, so the implant would not remain in the artery for too long. On top of that, the rats' arteries appeared healthy when the wires were removed, with tissue firmly grasping the implant.

"Plus, zinc reduces atherosclerosis," he added, referring to zinc's well-known ability to fight the development of plaque in the arteries. "How cool is that? A zinc stent might actually have health benefits."

There is one drawback. "A stent made of conventional zinc would not be strong enough to hold open a human artery," he said. "We need to beef it up, double the strength."

"The good news is that there are commercial zinc alloys that are up to three times stronger," Bowen said. "We know we can get there. We just don't want to ruin our corrosion behavior."

The researchers have filed a provisional patent on their discoveries and are now testing new zinc-based stent materials.

An article on their work, "Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents," was recently published in the journal Advanced Materials.

Bowen's research is supported by a two-year, $52,000 predoctoral fellowship from the American Heart Association. Initial research was supported by a summer fellowship from the DeVlieg Foundation.

Bowen's advisor is Jaroslaw Drelich, a professor of materials science and engineering, and they work in close collaboration with Jeremy Goldman, an associate professor of biomedical engineering. Undergraduates Jacob Braykovich and Matt Tianen are also working on material development and corrosion testing related to the project.

Share this story on Facebook, Twitter, and Google:

Other social bookmarking and sharing tools:


Story Source:

The above story is reprinted from materials provided by Michigan Technological University. The original article was written by Marcia Goodrich.

Note: Materials may be edited for content and length. For further information, please contact the source cited above.


Journal Reference:

  1. Patrick K. Bowen, Jaroslaw Drelich, Jeremy Goldman. Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents. Advanced Materials, 2013; DOI: 10.1002/adma.201300226

Note: If no author is given, the source is cited instead.

Disclaimer: This article is not intended to provide medical advice, diagnosis or treatment. Views expressed here do not necessarily reflect those of ScienceDaily or its staff.

Source: http://feeds.sciencedaily.com/~r/sciencedaily/~3/0zyu7mRzULY/130430194409.htm

EJ Manuel Dion Jordan Omar Borkan Al Gala kylie bisutti jimmy carter lunar eclipse Sunil Tripathi

No comments:

Post a Comment